To offset addresses in the trace list
•
Choose Trace
→
Display Options... and in the dialog box, enter the desired offset
value in the field beside Address Offset. Then click the OK or Apply pushbutton.
•
Use the offset_by command-line option to the display trace command.
The Address Offset or offset_by trace display options allow you to cause the
address information in the trace display to be offset by the amount specified. The
offset value is subtracted from the instruction’s physical address to yield the
address that is displayed.
If code gets relocated and therefore makes symbolic information obsolete, you can
use the Address Offset or offset_by option to change the address information so
that it again agrees with the symbolic information.
You can also specify an offset to cause the listed addresses to match the addresses
in compiler or assembler listings.
Example
Trace execution from entry of the demo program (the main label) then offset by the
value of main so that the addresses appear the same as the location counter in the
assembler listing:
reset
trace
run from transfer_address
display trace offset_by main
Chapter 7: Using the Emulation-Bus Analyzer
Displaying the Trace List
201
Содержание 64780A
Страница 1: ...Graphical User Interface User s Guide MC68360 68EN360 Emulator Analyzer HP 64780A ...
Страница 20: ...xx ...
Страница 21: ...Part 1 Quick Start Guide 1 ...
Страница 23: ...1 Getting Started 3 ...
Страница 45: ...Part 2 Using The Emulator 25 ...
Страница 47: ...2 Plugging into a Target System 27 ...
Страница 55: ...Chapter 2 Plugging into a Target System Plugging into the Motorola QUADS Target System 35 ...
Страница 59: ...3 Starting and Exiting HP 64700 Interfaces 39 ...
Страница 69: ...4 Entering Commands 49 ...
Страница 103: ...5 Configuring the Emulator 83 ...
Страница 122: ...102 ...
Страница 123: ...6 Using the Emulator 103 ...
Страница 193: ...7 Using the Emulation Bus Analyzer How to record program execution in real time 173 ...
Страница 249: ...8 Making Software Performance Measurements 229 ...
Страница 279: ...9 Making Coordinated Measurements 259 ...
Страница 295: ...Part 3 Reference 275 ...
Страница 297: ...10 Setting X Resources 277 ...
Страница 312: ...292 ...
Страница 313: ...11 Emulator Analyzer Interface Commands 293 ...
Страница 391: ...set Chapter 11 Emulator Analyzer Interface Commands set 371 ...
Страница 405: ... SYMB Chapter 11 Emulator Analyzer Interface Commands SYMB 385 ...
Страница 422: ...402 ...
Страница 460: ...440 ...
Страница 461: ...Part 4 Concept Guide 441 ...
Страница 463: ...13 Concepts of the EMSIM and EMRAM 443 ...
Страница 471: ...Part 5 Installation and Service Guide 451 ...
Страница 473: ...14 Installation 453 ...
Страница 491: ...Chapter 14 Installation Verifying the Installation 471 ...
Страница 493: ...15 Installing Updating Emulator Firmware 473 ...
Страница 500: ...480 ...
Страница 516: ...496 ...
Страница 540: ...520 ...