To specify both sequencing and windowing
•
Create your first specification form on the command line. That will enter the
proper format in the Trace Specification Selection dialog box. Obtain that dialog
box by choosing Trace
→
Trace Spec... You can click on your specification in the
dialog box, edit it if desired, and click OK.
•
Using the command line, enter commands as follows:
•
Specify a trace sequence that starts with a window and ends with a trigger by
entering:
trace enable <bus_state> disable <bus_state>
find_sequence <bus_state> occurs <#times> [then
<bus_state>
occurs <#times>] trigger <bus_state>
<bus_state> represents a combination of address, data and status expressions that
must be matched to satisfy the trigger or sequence qualifier. <#times> is the
number of times that bus state must occur to satisfy the qualifier.
You can use the sequencing and windowing specifications together to make
specification of complex qualifiers easier. If you use the windowing specification,
the sequence specification is limited to four sequence terms. Also, note that when
you use a windowing specification, you cannot use a restart term with your
sequence specification.
Example
Use the analyzer sequencer to trace states occurring between the start of the
example program and the call to the message interpreter, then trigger after access to
the variable that stores the value of current humidity, but only if it is accessed after
a specific series of events:
trace enable main disable proc_spec find_sequence
update_sys.get_targets
then long_aligned
update_sys.write_hdwr
trigger after current_humid
Chapter 7: Using the Emulation-Bus Analyzer
Making Complex Trace Measurements
215
Содержание 64780A
Страница 1: ...Graphical User Interface User s Guide MC68360 68EN360 Emulator Analyzer HP 64780A ...
Страница 20: ...xx ...
Страница 21: ...Part 1 Quick Start Guide 1 ...
Страница 23: ...1 Getting Started 3 ...
Страница 45: ...Part 2 Using The Emulator 25 ...
Страница 47: ...2 Plugging into a Target System 27 ...
Страница 55: ...Chapter 2 Plugging into a Target System Plugging into the Motorola QUADS Target System 35 ...
Страница 59: ...3 Starting and Exiting HP 64700 Interfaces 39 ...
Страница 69: ...4 Entering Commands 49 ...
Страница 103: ...5 Configuring the Emulator 83 ...
Страница 122: ...102 ...
Страница 123: ...6 Using the Emulator 103 ...
Страница 193: ...7 Using the Emulation Bus Analyzer How to record program execution in real time 173 ...
Страница 249: ...8 Making Software Performance Measurements 229 ...
Страница 279: ...9 Making Coordinated Measurements 259 ...
Страница 295: ...Part 3 Reference 275 ...
Страница 297: ...10 Setting X Resources 277 ...
Страница 312: ...292 ...
Страница 313: ...11 Emulator Analyzer Interface Commands 293 ...
Страница 391: ...set Chapter 11 Emulator Analyzer Interface Commands set 371 ...
Страница 405: ... SYMB Chapter 11 Emulator Analyzer Interface Commands SYMB 385 ...
Страница 422: ...402 ...
Страница 460: ...440 ...
Страница 461: ...Part 4 Concept Guide 441 ...
Страница 463: ...13 Concepts of the EMSIM and EMRAM 443 ...
Страница 471: ...Part 5 Installation and Service Guide 451 ...
Страница 473: ...14 Installation 453 ...
Страница 491: ...Chapter 14 Installation Verifying the Installation 471 ...
Страница 493: ...15 Installing Updating Emulator Firmware 473 ...
Страница 500: ...480 ...
Страница 516: ...496 ...
Страница 540: ...520 ...