Range resource in use (Error 1221)
Cause: This error occurs when you attempt to redefine the “complex” configuration
range resource while it is currently being used as a qualifier in the trace
specification.
Action: In the “complex” configuration, display the sequencer specification to see
where the range resource is being used and remove it; then, you can redefine the
range resource.
Range term used more than once (Error 1248)
Cause: This error occurs when you attempt to use the range resource more than
once in a sequencer branch expression.
Action: Do not try to use the range resource more than once in a sequencer branch
expression.
Read PC failed during break (Error 603)
Cause: The monitor is not responding.
Action: Check your target system configuration, the emulator configuration and
memory map, or reinitialize the emulator. Then try the command sequence again.
Record checksum failure (Error 400)
Cause: During a transfer operation, the checksum specified in a file did not agree
with that calculated by the HP 64700.
Action: Retry the transfer operation. If the failure is repeated, make sure that both
your host and the HP 64700 data communications parameters are configured
correctly.
Records expected: <number>; records received: <number> (Error 401)
Cause: The HP 64700 received a different number of records than it expected to
receive during a transfer operation.
Action: Retry the transfer. If the failure is repeated, make sure the data
communications parameters are set correctly on the host and on the HP 64700. See
the HP 64700-Series Card Cage Installation/Service Guide for details.
Chapter 12: Emulator Error Messages
Range resource in use (Error 1221)
428
Содержание 64780A
Страница 1: ...Graphical User Interface User s Guide MC68360 68EN360 Emulator Analyzer HP 64780A ...
Страница 20: ...xx ...
Страница 21: ...Part 1 Quick Start Guide 1 ...
Страница 23: ...1 Getting Started 3 ...
Страница 45: ...Part 2 Using The Emulator 25 ...
Страница 47: ...2 Plugging into a Target System 27 ...
Страница 55: ...Chapter 2 Plugging into a Target System Plugging into the Motorola QUADS Target System 35 ...
Страница 59: ...3 Starting and Exiting HP 64700 Interfaces 39 ...
Страница 69: ...4 Entering Commands 49 ...
Страница 103: ...5 Configuring the Emulator 83 ...
Страница 122: ...102 ...
Страница 123: ...6 Using the Emulator 103 ...
Страница 193: ...7 Using the Emulation Bus Analyzer How to record program execution in real time 173 ...
Страница 249: ...8 Making Software Performance Measurements 229 ...
Страница 279: ...9 Making Coordinated Measurements 259 ...
Страница 295: ...Part 3 Reference 275 ...
Страница 297: ...10 Setting X Resources 277 ...
Страница 312: ...292 ...
Страница 313: ...11 Emulator Analyzer Interface Commands 293 ...
Страница 391: ...set Chapter 11 Emulator Analyzer Interface Commands set 371 ...
Страница 405: ... SYMB Chapter 11 Emulator Analyzer Interface Commands SYMB 385 ...
Страница 422: ...402 ...
Страница 460: ...440 ...
Страница 461: ...Part 4 Concept Guide 441 ...
Страница 463: ...13 Concepts of the EMSIM and EMRAM 443 ...
Страница 471: ...Part 5 Installation and Service Guide 451 ...
Страница 473: ...14 Installation 453 ...
Страница 491: ...Chapter 14 Installation Verifying the Installation 471 ...
Страница 493: ...15 Installing Updating Emulator Firmware 473 ...
Страница 500: ...480 ...
Страница 516: ...496 ...
Страница 540: ...520 ...