Ranging
(continued)
•
Front-Panel Operation
: Use the front-panel
RANGE
keys to select
autoranging or manual ranging. For frequency and period
measurements from the front panel, ranging applies to the signal’s
input
voltage
, not its frequency.
See also “To Select a Range,” on page 20.
•
Remote Interface Operation
: You can set the range using any of the
following commands.
CONFigure:<
function
> {<
range
>|MIN|MAX|DEF},{<
resolution
>|MIN|MAX|DEF}
MEASure:<
function
>? {<
range
>|MIN|MAX|DEF},{<
resolution
>|MIN|MAX|DEF}
<
function
>:RANGe {<
range
>|MINimum|MAXimum}
<
function
>:RANGe:AUTO {OFF|ON}
Chapter 3 Features and Functions
Measurement Configuration
62
Содержание 34401A
Страница 12: ...1 Quick Start 1 ...
Страница 26: ...2 Front Panel Menu Operation 2 ...
Страница 50: ...3 Features and Functions 3 ...
Страница 103: ...4 Remote Interface Reference 4 ...
Страница 135: ...SCPI Status System 4 Chapter 4 Remote Interface Reference The SCPI Status Model 135 ...
Страница 170: ...5 Error Messages 5 ...
Страница 182: ...6 Application Programs 6 ...
Страница 196: ...7 Measurement Tutorial 7 ...
Страница 214: ...8 Specifications 8 ...
Страница 222: ...Product Dimensions TOP Product Dimensions All dimensions are shown in millimeters 8 Chapter 8 Specifications 223 ...