background image

G 17, Bharat Industrial Estate, T. J. Road, 

Sewree (W), Mumbai - 400 015. INDIA. 

 (022) 24156638

Sales Direct :

 (022) 24124540, 24181649. 

 (022) 24149659

Tel. :

Fax :

 [email protected] 

Email :

www.

 

Website : 

kusamelectrical.com

              www.kusam-meco.co.in

®

LIST OF PRODUCTS

 Digital Multimeter                    

 Digital AC & AC/DC Clampmeter

 AC Clamp Adaptor                  

 AC/DC Current Adaptor

 Thermo Anemometer               

 Thermo Hygrometer

 Distance Meter                        

 Digital Lux Meter

 Network Cable Tester              

 Power Factor Regulator

 Earth Resistance Tester           

 Digital Panel Meters

 DC Power Supplies                 

 High Voltage Detector

 Calibrators                               

 Gas Analysers

 Frequency Counter                  

 Function Generator

 Phasing Sticks                         

 Battery Tester

 Waterproof Pen Testers           

 Solar Power Meter

 EMF Detector

 Wood, Paper & Grain Moisture Meter

 Transistorised Electronic Analog & Digital Insulation   

    Resistance Testers(upto 10 KV)

 Digital Sound Level Meter & Sound Level Calibrator

 Digital contact & Non-contact Type Tachometer

 Digital Non-contact (infrared) Thermometer

 Maximum Demand Controller/Digital Power Meter

 Digital Hand Held Temperature Indicators

 

 

APO RS232

R MAX-MIN R Q

D

AUTO H SET

TOL AVG

PAL SER

LC
R

LCR METER
DUAL DISPLAY

FREQ

SET

TOL

RANGE

REL

MAX

LIMITS

HOLD

MIN

Hi oL

1

2

5

8

ENTER

4

7

PAL
SER

0

DO NOT APPLY VOLTAGE TO INPUT TERMINALS

DISCHARGE CAPACITOR BEFORE TESTING

AUTO-POWER OFF

   

%

1kHz

120Hz

%

mH

m  npF

3

6

9

 

OPERATION MANUAL

®

AN ISO 9001:2015 COMPANY

MODEL KM-459

Содержание KM-459

Страница 1: ...nction Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain Moisture Meter Transistorised Electronic Analog Digital Insulation Resistance Testers upto 10 KV Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermometer Maximum Demand Controller Digital Power Meter Digit...

Страница 2: ...orage environment 20 C to 60 C at 0 to 80 RH with battery removed from meter Power Single standard 9 volt battery NEDA 1604 JIS 006P IEC 6F22 External power Minimum 12V maximum 15V and at least minimum 50mA Auto power As the APO is displayed on the LCD the meter will shut down by itself if unused for about 10 minutes press the power key to resume power on mode The meter will cancel auto power off ...

Страница 3: ...2 Communication is activated annunciator R Recording mode annunciator MAX Maximum reading annunciator MIN Minimum reading annunciator AVG Average reading annuciator AUTO Autoranging indicator H Data hold annunciator SET Set mode annunciator Relative mode annunciator TOL Tolerance mode annunciator PAL Parallel mode annunciator SER Series mode annunciator D Dissipation factor annunciator Q Quality f...

Страница 4: ... the battery power is weakening Beeper tone indicator for tolerance mode MKΩ umH nd u Ictance Henry annunciator munpF Capacitance ara annunciator SPECIFICATIONS CAPACITANCE Test Frequency 120Hz 10mF 1 F μ 10nF 1nF 10pF 1pF 2000 F μ 200μ F 20μ F 2000nF 200nF 20nF Range Min Max Cx DF Note Resistance O mhannunciator ...

Страница 5: ...KHz 2000 F μ 10nF 1nF 10pF 1pF 0 1pF 200 F μ 20μ F 2000nF 200nF 20nF 2000pF Range Min Max Cx DF Note INDUCTANCE Test Frequency 120Hz Range 1H 10000H 1mH 10 H μ 1 H μ 2000H 200H 20H 200mH 20mH Min Max Lx DF 0 5 DF DF 0 5 Note ...

Страница 6: ... H μ 1 H μ 2000H 200H 20H 200mH 20mH 2000 H μ Range Min Max Lx DF 0 5 DF DF 0 5 Note RESISTANCE 10MΩ 2MΩ 200KΩ 20KΩ 2KΩ 200Ω 20Ω Note In 20 range effective readings must over 20 counts Range Min Max Test Freq 120Hz Note Test Freq 1KHz ...

Страница 7: ...cked and damaged Please check periodically To avoid electric shock discharge the circuits completely before taking any measurements CAUTION When it appears to have abnormal situations such as you cannot turn on the meter to operate 1 It is normal situation when you cannot turn on the meter after turning off the meter just for few seconds Please wait a moment to turn it on again 2 When you cannot o...

Страница 8: ...ies equivalent circuit mode SER 4 RANGE BUTTON Press RANGE button to select the Manual Range mode and turn off the AUTO annunciator The meter remains in the range it was in when manual ranging was selected In the Manual Range mode Each time you press RANGE button the range and the input range annunciator increments and a new value is displayed To exit the Manual Range mode and return to autorangin...

Страница 9: ... Press Min Max to enter the Min Max Avg mode and stop the auto shut down function In Addition to power and hold key the other keys cannot be activated When the meter samples about 6 times and then beeper will emit a sound When a new Max Min data being recorded and then beeper will emit 2 sounds Main display value second display value cycles through Min Max key present value parameter value Max val...

Страница 10: ... HI LO LIMITS ONLY MAIN DISPLAY Press Hi Lo LIMITS to enter the Hi Lo LIMITS mode and change to manual range mode the original Hi LO LIMITS value and annunciators appear in the same time individually When the input exceeds Hi limits the is blinking and emits a continuous tone When the input goes below the Lo limits the is blinking and the beeper emits a pulse tone This warns users that out of sett...

Страница 11: ...will sound Replace fuse only with the original type 0 1A 250V fast acting fuse Cleaning Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents RS 232 COMMAND TABLE Use IR as the interface of Data transmission and use external computer to start RS 232 functions RS 232 Interface Parameter Baud rate 1200 Parity check EVEN Data buts 7 Stop bits 1 1 Setup Selections...

Страница 12: ...etting value V 19999 Limits Hi setting value W 19999 Limits Lo setting value X 19999 TOL SET setting value Y 19999 TOL SET Hi setting value Z 19999 TOL SET Lo setting value After receiving of setting data from PC U V W X Y Z and will send out the receiving data again then it is convenient for PC to check the accuracy of data output are total 7 digits c Command BXXXXXX Exit the SETUP mode 2 Read Da...

Страница 13: ... OL 28 S SET _ normal 29 F FUSE _ normal 30 H HOLD _ normal 31 R Present value M Maximum value I Minimum value X Max Min value A Average value _ normal 32 R REL S REL SET _ normal 33 L LIMITS _ normal 34 T TOL S TOL SET _ normal 35 B Backlight _ normal 36 A Adapter insert _ normal 37 B Low Battery _ normal 38 CR ASCII 0DH 39 nl LF ASCII 0AH ...

Страница 14: ... 22 4 RS 232 Output Chart for Second Display Rs 100Ω R Rs 1KΩ 10ΚΩ R Rs 100KΩ 1 2 3 4 5 5 FORMULA RP RS 1 Q2 CP CS 1 1 D2 CS CP 1 D2 LP LS 1 1 Q2 LS LP Q2 1 Q2 Range Q D R ...

Отзывы: