Installation and safety references
Before installation
,
handling or operation of the device
,
please read through this operating instructions
completely and carefully.
This controller fulfils the European Directives of security and EMC. It is the responsibility of the operator
to observe the directives at installation of the device.
CE marking
The device complies with the European Directives for electromagnetic compatibility (complies with EN 61326-1)
and low voltages (complies with EN 61010-1).
Service and repair
This device is maintenance free.
If the controller should indicate a fault
,
please contact
H
otset Gmb
H
. Customer repairs are not permissible.
Cleaning
Employ no water or cleaning agents based on water for the cleaning of the device stick-on labels. You can clean
the surface of the devices with a mild soap solution.
Storage
If you should not put the device into operation immediately after unpacking
,
protect it against moisture and coarse
dirt.
Personnel
The installation of the device may by carried out by qualified personnel only.
Wiring
The wiring system must be implemented correctly according to the specifications in this operating manual. All
feeds and connecting terminals must be dimensioned for the corresponding amperage. Furthermore
,
all connec-
tions are to be carried out according to the valid VDE Specification and/or the respective national specifications.
Ensure in particular that the AC power supply is not connected with the logic output or the low-voltage in-
put.
Overload protection
For the power supply of the controller and the controller outputs use a fuse protection or a circuit breaker. That
protects the printed circuit board against overload.
Maximum Voltage for Devices with Power Supply of 85...250VAC
For controllers with a power supply of 85...250VAC the maximum applied voltage on the terminals has to be less
than 250 VAC.
DO NOT connect the controller to three phase systems or grounded midpoints. In case of an error the voltage of
the power supply can exceed 250 VAC. Under these circumstances the device is not reliable.
Voltage transients on power supply terminals and between power supply and ground should not exceed 2.5 kV.
For transients expect to exceed 2.5 kV
,
the power supply voltage should be limited to 2.5 kV by an over voltage
protection.
Environment
Conducting contamination must not reach the proximity of the device connecting terminals in the control cabinet.
In order to achieve suitable ambient air conditions
,
install an air filter in the air inlet of the control cabinet. If the
controller should be in a condensing environment (low temperatures)
,
install a thermostat-controlled heating unit
in the control cabinet.