62
6. KM-1301SRJ3 with URC-14F
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
10.7 A
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2120 (3.83)
2020 (3.38)
WATER gal./24HR (gal./100 lbs.)
186 (14.0)
466 (32.6)
ICE PRODUCTION PER CYCLE
28.9 lbs. (13.1 kg) 1440pcs.
BIN CONTROL SYSTEM
Mechanical
REFRIGERANT CHARGE
TOTAL R404A, 10 lb. 5.8 oz. (4700g)
ICEMAKER, 5 lb. 15.2 oz. (2700g)
CONDENSER, 4 lb. 6.5 oz. (2000g)
Performance Data Sheet
70/21
1433
650
1403
636
1353
614
80/27
1410
640
1363
618
1309
594
90/32
1403
636
1330
603
1276
579
lbs./day kg./day
100/38
1390
631
1317
598
1227
557
70/21
80/27
90/32
watts
100/38
70/21
466
1.77
384
1.45
347
1.31
80/27
404
1.53
276
1.05
281
1.06
90/32
384
1.45
186
0.70
172
0.65
gal./day m
3
/day
100/38
293
1.11
183
0.69
160
0.60
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
222
15.6
239
16.8
256
18.0
80/27
235
16.5
261
18.4
275
19.3
90/32
239
16.8
280
19.7
296
20.8
PSIG kg/cm
2
G
100/38
240
16.9
284
19.9
310
21.8
70/21
58
4.1
59
4.1
59
4.2
80/27
58
4.1
59
4.2
60
4.2
90/32
59
4.1
60
4.2
61
4.3
PSIG kg/cm
2
G
100/38
59
4.1
60
4.2
61
4.3
18,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
2,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME
133 CU. IN. (URC-14F)
2.0
HEAD PRESSURE
SUCTION PRESSURE
28
30
38
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
3.8
3.3
3.1
3.4
2.6
2.7
3.3
2.0
2.0
2.7
2.0
2055
2129
2190
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
26
27
31
27
28
33
27
29
34
APPROXIMATE ELECTRIC
CONSUMPTION
2020
2049
2086
2042
2088
2123
2049
2120
2156
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205