61
5. KM-1301SRJ with URC-14F
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/1
AMPERAGE
13.5 A
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2250(4.28)
2070(3.55)
WATER gal./24HR (gal./100 lbs.)
176(14.0)
511(36.5)
ICE PRODUCTION PER CYCLE
29.4 lbs. (13.3 kg) 1440pcs.
BIN CONTROL
Mechanical
REFRIGERANT CHARGE
TOTAL R404A, 10 lb. 5.8 oz. (4700g)
ICEMAKER, 5 lb. 15.2 oz. (2700g)
CONDENSER, 4 lb. 6.5 oz. (2000g)
Performance Data Sheet
70/21
1400
635
1359
616
1287
584
80/27
1369
621
1305
592
1225
556
90/32
1359
616
1260
572
1182
536
lbs./day kg./day
100/38
1339
608
1242
563
1110
503
70/21
80/27
90/32
watts
100/38
70/21
511
1.93
413
1.56
381
1.44
80/27
436
1.65
284
1.07
310
1.17
90/32
413
1.56
176
0.67
177
0.67
gal./day m
3
/day
100/38
309
1.17
177
0.67
178
0.67
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
222
15.6
239
16.8
254
17.9
80/27
235
16.5
261
18.4
272
19.1
90/32
239
16.8
280
19.7
293
20.6
PSIG kg/cm
2
G
100/38
239
16.8
283
19.9
305
21.4
70/21
57
4.0
58
4.0
58
4.1
80/27
57
4.0
58
4.1
59
4.1
90/32
58
4.0
59
4.1
60
4.2
PSIG kg/cm
2
G
100/38
58
4.1
59
4.2
60
4.2
18,900 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
2,700 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME
133 CU. IN. (URC-14F)
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC
CONSUMPTION
2070
2123
2148
2110
2192
2191
2123
2250
2260
2112
2252
2270
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
27
28
30
28
30
32
28
32
34
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.2
3.5
3.3
3.7
2.7
2.9
3.5
2.1
2.1
2.9
2.1
2.1
HEAD PRESSURE
SUCTION PRESSURE
29
32
36
ENG.F-011.1.0205