9. KM-1601SWJ
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/1 (3 WIRE WITH NEUTRAL FOR 115V)
AMPERAGE
13.6 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2270 (3.30)
2280 (3.30)
WATER gal./24HR (gal./100 lbs.)
325 (19.7)
646 (38.9)
WATER COOLED CONDENSER
1650 (100)
974 (59)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
30.8 lbs. (14 kg) 1440pcs.
BIN CONTROL SYSTEM
Mechanical
REFRIGERANT CHARGE
R404A, 2 lb. 10.3 oz. (1200g)
Performance Data Sheet
70/21
1660
753
1657
752
1578
716
80/27
1658
752
1653
750
1533
695
90/32
1657
752
1650
748
1546
701
lbs./day kg./day
100/38
1616
733
1626
737
1450
658
70/21
80/27
90/32
watts
100/38
70/21
1620
6.13
1724
6.53
2262
8.56
80/27
1699
6.43
1861
7.04
2619
9.91
90/32
1724
6.53
1975
7.48
2651
10.04
gal./day m
3
/day
100/38
2049
7.76
2133
8.08
3273
12.39
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
243
17.1
245
17.2
269
18.9
80/27
245
17.2
248
17.4
284
20.0
90/32
245
17.2
250
17.6
282
19.8
PSIG kg/cm
2
G
100/38
257
18.1
257
18.1
311
21.9
70/21
45
3.2
45
3.2
47
3.3
80/27
45
3.2
45
3.2
48
3.4
90/32
45
3.2
45
3.2
48
3.3
PSIG kg/cm
2
G
100/38
46
3.2
46
3.2
50
3.5
21,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
126 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC
CONSUMPTION
2280
2277
2334
2278
2273
2365
2277
2270
2348
2309
2288
2420
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
23
23
24
23
24
25
23
24
25
23
24
26
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.4
3.9
3.6
4.0
3.3
3.2
3.9
2.8
2.6
3.3
2.7
2.4
HEAD PRESSURE
SUCTION PRESSURE
ENG.F-011.1.0205