42
C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions for both the 2A7664 -01
and 2A7664-02 control boards:
S4 Dip Switch
S4 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KM-1301S_J
KM-1601S_J/3
ON OFF OFF OFF OFF OFF ON OFF OFF OFF
KM-1301S_J3
OFF OFF OFF OFF OFF OFF ON OFF OFF OFF
KM-190S_J/3
KM-2200S_J3
KM-2600S_J3
OFF OFF OFF OFF ON OFF ON OFF OFF OFF
S5 Dip Switch (Do Not Adjust)
S5 Dip Switch No. 1
2
3
4
5
All
OFF OFF OFF OFF ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5)
Pump-Out Time (3 & 4)
Harvest Timer (1 & 2)
Factory Use (8)
Harvest Pump Time (Harvest Assist) and Freeze-Time Correction (7)
(Do Not Adjust)
1
2
3
4
5
6
7
8
9
10
ON
S4 Dip Switch
"J" Control Board
1
2
3
4
5
ON
S5 Dip Switch
(
Do Not Adjust)
"J" Control Board
Refill Counter (2 and 3)
Float Switch Selector (1)
Minimum Harvest Time (4)
Anti-Slush (5)
Harvest Pump Time Timer (Harvest Assist) (6)