66
10. KM-1601SWJ3
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
8.8 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2300 (3.32)
2290 (3.29)
WATER gal./24HR (gal./100 lbs.)
307 (18.5)
578 (34.6)
WATER COOLED CONDENSER
1494 (90)
932 (56)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
31.5 lbs. (14.3 kg) 1440pcs.
BIN CONTROL SYSTEM
Mechanical
REFRIGERANT CHARGE
R404A, 2 lb. 10.3 oz. (1200g)
Performance Data Sheet
70/21
1671
758
1668
756
1557
706
80/27
1669
757
1664
755
1494
678
90/32
1668
756
1660
753
1513
686
lbs./day kg./day
100/38
1610
730
1626
737
1378
625
70/21
80/27
90/32
watts
100/38
70/21
1511
5.72
1596
6.04
2144
8.12
80/27
1575
5.96
1708
6.46
2496
9.45
90/32
1596
6.04
1801
6.82
2500
9.46
gal./day m
3
/day
100/38
1908
7.22
1965
7.44
3142
11.89
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
290
20.4
292
20.5
299
21.0
80/27
292
20.5
295
20.7
303
21.3
90/32
292
20.5
297
20.9
305
21.4
PSIG kg/cm
2
G
100/38
295
20.7
299
21.0
312
21.9
70/21
50
3.5
50
3.5
55
3.8
80/27
50
3.5
51
3.6
57
4.0
90/32
50
3.5
51
3.6
57
4.0
PSIG kg/cm
2
G
100/38
53
3.7
52
3.7
62
4.4
19,900 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
121 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
3.2
2.7
2.4
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.2
3.8
3.5
3.9
3.2
3.1
3.8
2.7
2.5
25
23
24
26
24
25
27
2300
2305
2340
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
23
23
24
23
24
APPROXIMATE ELECTRIC
CONSUMPTION
2290
2293
2309
2292
2297
2320
2293
2300
2321
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205