59
3. KM-1301SWJ
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/1
AMPERAGE
8.2 A
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1930(3.76)
1900(3.66)
WATER gal./24HR (gal./100 lbs.)
258(21.0)
479(38.4)
WATER COOLED CONDENSER
1095(89)
682(55)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
28.5 lbs. (12.9 kg) 1440pcs.
BIN CONTROL SYSTEM
Mechanical
REFRIGERANT CHARGE
R404A, 2 lb. 2.4 oz. (975g)
Performance Data Sheet
70/21
1247
566
1242
563
1234
560
80/27
1243
564
1235
560
1226
556
90/32
1242
563
1230
558
1221
554
lbs./day kg./day
100/38
1240
562
1228
557
1213
550
70/21
80/27
90/32
watts
100/38
70/21
1161
4.40
1217
4.61
1704
6.45
80/27
1204
4.56
1291
4.89
2006
7.59
90/32
1217
4.61
1353
5.12
1982
7.50
gal./day m
3
/day
100/38
1477
5.59
1500
5.68
2559
9.69
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
252
17.7
254
17.8
257
18.1
80/27
253
17.8
256
18.0
260
18.3
90/32
254
17.8
258
18.1
262
18.4
PSIG kg/cm
2
G
100/38
255
17.9
259
18.2
265
18.6
70/21
61
4.3
61
4.3
62
4.3
80/27
61
4.3
61
4.3
62
4.4
90/32
61
4.3
61
4.3
62
4.4
PSIG kg/cm
2
G
100/38
61
4.3
61
4.3
63
4.4
20,900 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
2,700 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
99 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
3.5
3.1
2.5
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.2
3.9
3.5
4.0
3.5
3.2
3.9
3.2
2.8
31
29
29
31
29
30
32
1910
1932
1950
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
28
29
30
29
29
APPROXIMATE ELECTRIC
CONSUMPTION
1900
1909
1919
1907
1920
1930
1909
1930
1940
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205