[b] Condenser
1) Remove the front panel (lower), move the control switch to the “OFF” position, and then
unplug the appliance.
2) Remove the control box and air guide from the machine compartment.
3) Remove the access valve from the condenser shroud to recover the refrigerant from
the valve.
4) Unscrew the condenser, and pull out the condenser.
5) The shroud, fan motor and drier come off together with the condenser.
6) Remove the screws fixing the shroud to the condenser from the machine compartment
side. (The fan motor is fixed to the shroud.)
7) Remove the copper tubes from the condenser using brazing equipment.
8) Pull out the condenser from the front side.
9) Replace the condenser, and braze the copper tubes.
10) Replace the removed parts in the reverse order of the removal procedure.
Note: When replacing the condenser in its correct position, be sure to insert the bottom
of the shroud into the base hook.
[c] Hot Gas Valve
1) Remove the front panel (lower) and rear panel, move the control switch to the “OFF”
position, and then unplug the appliance.
2) Remove the control box and air guide from the machine compartment.
3) Remove the hot gas valve coil from the hot gas valve body.
4) Remove the access valve from the condenser shroud, and recover the refrigerant from
the access valve.
5) Remove the copper tube from the hot gas valve body using brazing equipment.
6) Replace hot gas valve, and braze the copper tubes.
7) Replace the removed parts in the reverse order of the removal procedure.
3D̲prt
B
C
D
E
F
G
A
6
5
3
4
2
1
A
B
C
D
E
F
G
H
1
2
3
4
5
6
201802
3J
50
0
50
DRAWING No.
(30)
TITLE
(20)
メイショウ
図番
( )
DRAWN
DESIGNED
CHECKED
APPROVED
DATE
SCALE
UNIT
mm
ホシザキ株式会社
HOSHIZAKI CORPORATION
山崎
アイスキューバAY
野津
石富
1H6250A
2020.01.09
石富
1:10
1
No.
PARTS CODE
NAME & SPEC.
Q'TY
Z
0 1H6250A01
アイスキューバAY
0
寸法区分
普通寸法公差(±)単位mm
角度差(±) 指示なき取
付穴のピッ
チとその累
積公差は
O
O
4以下
0.05 0.1 0.2 0.3 0.5
1
3
6
4をこえ 16〃
0.1 0.2 0.3 0.5 0.7
1
2
3
16〃 63〃
0.2 0.3 0.5 0.7 1.2 20'
1
2
63〃 250〃
0.3 0.5 0.7 1.2 2.0 10' 20'
1
250〃 1000〃
0.5 0.7 1.2 2.0 3.0
5'
10' 30'
1000をこえる
0.7 1.2 2.0 3.0 5.0
5'
10' 30'
J
K L M N JK LM N
1
1 2020.02.21
品番63追加
石富 山崎
SYMBOL
P
DATE
REVISION
DESIGNED APPROVED
表
面
処
理
等
全
面
不動態化処理
焼痕除去
脱脂洗浄
焼痕銀粉塗布
バリ無きこと
/
C-C
1:5
Air Guide
Control Box
Access Valve
Compressor
Start Capacitor
Snap Pin
Содержание IM-50BAA-Q
Страница 52: ...51 C Wiring Diagram ...