Control Board (CB) Setting Menu
Category
No. Item
Range
Default
Water Supply
10 Harvest Cycle Water Supply Time: Water Temperature
Lower Than 13°C
Time to supply harvesting water to melt ice on water
plate at water supply temp lower than 13°C. Adjustable
between 1 and 99 sec. When set to "99", harvesting water
keeps running until evaporator (cube control) thermistor
senses harvesting completion temp.
1 to 99 sec,
99=continuous
(1 sec. increments)
1
11
Harvest Cycle Water Supply Time: Water Temperature
13°C or Higher
Time to supply harvesting water to melt ice on water
plate at water supply temp of 13°C or higher. Adjustable
between 1 and 99 sec. When set to "99", harvesting water
keeps running until evaporator (cube control) thermistor
senses harvest completion temp.
1 to 99 sec,
99=continuous
(1 sec. increments)
1
12 Freeze Cycle Water Supply Time: Partial/Full Drain
Time to supply icemaking water depending on partial or
full drain flush.
0 to 90 sec.
(1 sec. increments)
0
13 Water Temperature Correction Value
Value added to correct the difference between the
temperature at the evaporator (cube control) thermistor
and actual water supply temperature.
+0 to +20K
(1K increments)
4
14 Partial/Full Drain Flush Selection
Selection between full and partial drain flush of icemaking
water plate in case of cloudy ice production even after
hard water control. Icemaking water supply time and
water plate overflow pipe direction need to be changed.
Partial=1; Full=0
0
15 Freeze Cycle Water Supply Time
Time to supply additional icemaking water required after
pump motor starts following normal icemaking water
supply time.
0 to 90 sec.
(1 sec. increments)
15
16 Low Water Detection Time
Time to detect low water within which pump motor starts
and reaches the target rotation speed. The longer set time
becomes, the easier low water detects. The shorter set
time becomes, the harder low water detects. No low water
detection when set to "0".
SETTING CHANGE IS INEFFECTIVE.
0 to 90 sec.
0=no detection
(1 sec. increments)
0
Other
20 Display Switching in Operation
Switches 7-segment display during operation.
"0": Display constantly shows "on".
"1": Display shows "on" for 3 min just after power supply
is turned on and then shows bar such as "_ _" based on
operational status.
SETTING CHANGE IS INEFFECTIVE.
0="on" constantly
displayed
1=bar displayed
0
21 Stackable Bin Control
Allows for stacked units to be controlled through one bin
control.
DO NOT ADJUST
Yes=1; No=0
1