15
2. Bin Control Cleaning
Scale may build up on BC. Scale can cause the actuator paddle and magnet to stick. In
this case, BC should be cleaned.
WARNING
CHOKING HAZARD:
Ensure all components, fasteners, and thumbscrews are
securely in place after the icemaker is serviced. Make sure that none have fallen
into the dispense unit/ice storage bin.
1) Remove the front panel and then move the control switch to the "OFF" position. Unplug
the appliance.
2) Remove the top panel, top insulation, and top sheet.
3) Clear any ice away from BC.
4) Carefully remove the BC cable from the cable ties in the evaporator case, then remove
the BC from the bin control bracket and move to the front of the icemaker for cleaning.
5) Remove the actuator paddle from the switch mount. See Fig. 1.
6) Wipe down BC with a mixture of 1 part of Hoshizaki "Scale Away" and 25 parts of warm
water. Rinse the parts thoroughly with clean water.
7) Reassemble BC and replace it in its correct position.
Note: If the magnet was removed for cleaning, be sure to replace it in its correct
position.
8) Replace the BC cable into the cable ties in the evaporator case, then replace the top
sheet, top insulation, and top panel.
9) Confirm CB wire harness connections are secure, then replace the control box cover in
its correct position.
10) Plug in the appliance. Move the control switch to the "ICE" position.
11) Replace the front panel in its correct position.
Legend:
BC
–bin control;
CB
–control board