46
Insulation Tube
Air Duct
Interior Fan Motor
Wire Retainer
Fan Cover
Handle Cap
Door Handle
[b] INTERIOR FAN MOTOR
1) Unplug the unit.
2) Disconnect the Interior Fan Motor
connector (blue) beside the Refrigeration
Unit.
3) Unscrew the Refrigeration Unit.
4) Slightly lift up the Refrigeration Unit, and
put the Interior Fan Motor leads inside
the cabinet.
5) Remove the Air Duct.
6) Remove the Interior Fan Motor from the
Air Duct.
7) To replace the removed parts, reverse
the above procedure. Cover the Interior
Fan Motor leads with the Insulation Tube
as a cushion through the hole in the
Refrigeration Unit.
Note: To prevent the leads from being caught between the Fan Blades, fix the leads with
the Wire Retainer inside the Air Duct before fitting the Air Duct.
6. DOOR PARTS
[a] DOOR HANDLE
The Door Handle is replaceable. Order the new
Door Handle and two Handle Caps. The Handle
Caps are damaged when removed and need to be
replaced together with the Door Handle.
1) Put a precision screwdriver into the notches to
remove the Handle Caps.
2) Unscrew and remove the Door Handle.
3) To replace the removed parts, reverse the above
procedure. Tighten the mounting screws to a
torque of 98 - 127 Nm
٠
cm (10 - 13 kgf
٠
cm).
Manual tightening with a screwdriver needs
additional tightening.
Содержание HFE-140B Series
Страница 6: ... 2 DIMENSIONS SPECIFICATIONS a HRE 70B ...
Страница 7: ... b HRE 140B ...
Страница 8: ... c HFE 70B ...
Страница 9: ... d HFE 140B ...
Страница 10: ... e HRE 70B F ...
Страница 11: ... f HRE 140B F ...
Страница 12: ... II TECHNICAL INFORMATION 1 WIRING DIAGRAM a HRE 70B ...
Страница 13: ...10 b HRE 140B ...
Страница 14: ...11 c HFE 70B ...
Страница 15: ...12 d HFE 140B ...
Страница 16: ...13 e HRE 70B F ...
Страница 17: ...14 f HRE 140B F ...
Страница 18: ...15 2 REFRIGERATION CIRCUIT Refrigerant HFC 134a HRE series HFC 404A HFE series ...