35
3. COMPONENTS
①
Safety Breaker
Safety Breaker trips
Locate earth leakage/short circuit
Safety Breaker splashed with water
Dry and replace if necessary
②
Power Supply Board Open circuit
Correct or replace
(in Relay Box)
Input/output (Controller Board, Interior Fan Motor)
Replace
Input: 115V AC Output: 12V DC
Controller Board output - K1 Connector No. 1, 2
Interior Fan Motor - See wiring label
Frame Heater voltage (K2 Connector No. 1, 3)
Replace
Heater ON: 0V
Heater OFF: 115V
Switches every 2 min
③
Controller Board
Connector/pin disconnected
Correct
Connector dusty/dirty
Remove
7 segment display partially/totally off
Replace
Electronic parts defective/burnt out
Replace
Ambient Temp Sensor damaged
Replace
(Frame Heater will be continuously energized)
Relay, Relay Board output (12V DC)
Replace
④
Relay
Fast-on terminal/pin disconnected
Correct
Connector dusty/dirty
Remove
Open circuit
Correct
Output to each load
Replace
Check with wiring diagram/timing chart
Abnormal noise
Replace
⑤
Interior Thermistor
Location (holder in front of Evaporator)
Correct
Disconnected, replaced with Defrost Thermistor, etc
Incorrect temp indication
Immerse in ice water to check resistance
(5 - 6.5kȍ) Replace if necessary
Short circuit (temp displayed as "HH")
Clean/dry connector
Replace
Open circuit (temp displayed as "-60")
Replace
⑥
Clog Thermistor
Abnormal resistance
Immerse in ice water to check resistance
(150 - 180kȍ) Replace if necessary
Short circuit
Clean/dry connector
Replace
Open circuit
Replace
⑦
Defrost Thermistor
Location (plug in from Evaporator front)
Correct
Disconnected, replaced with Interior Thermistor, etc
Abnormal resistance
Immerse in ice water to check resistance
(5 - 6.5kȍ) Replace if necessary
Short circuit
Clean/dry connector
Replace
Open circuit
Replace
⑧
Pressure Switch
Terminal splashed with water
Dry and replace if necessary
Terminal dusty/dirty
Remove
Conductivity between contacts
Replace if conductive
⑨
Compressor
Resistance between terminals
Replace
Compressor Winding Resistance (ȍ)
Primary Secondary
FR8.5G 8.9 12.0
SC18G 3.7 14.1
SC12CL 5.0 13.7
SC18CL 3.7 14.1
Insulation resistance 1Mȍ or more at 500V
Replace
Abnormal noise
Replace
Insufficient compression (discharge temp too low)
Replace if no gas leaks
CHART
NO.
COMPONENT
CHECK
REMEDY
Содержание HFE-140B Series
Страница 6: ... 2 DIMENSIONS SPECIFICATIONS a HRE 70B ...
Страница 7: ... b HRE 140B ...
Страница 8: ... c HFE 70B ...
Страница 9: ... d HFE 140B ...
Страница 10: ... e HRE 70B F ...
Страница 11: ... f HRE 140B F ...
Страница 12: ... II TECHNICAL INFORMATION 1 WIRING DIAGRAM a HRE 70B ...
Страница 13: ...10 b HRE 140B ...
Страница 14: ...11 c HFE 70B ...
Страница 15: ...12 d HFE 140B ...
Страница 16: ...13 e HRE 70B F ...
Страница 17: ...14 f HRE 140B F ...
Страница 18: ...15 2 REFRIGERATION CIRCUIT Refrigerant HFC 134a HRE series HFC 404A HFE series ...