HFE series duty ratio
Level 2: Factory adjustment
Level 6: Constantly ON
The heater control reduces the power consumption, and the less heat invasion into the
cabinet improves the refrigeration unit operating efficiency, resulting in significant energy
saving effects.
[b] INTERIOR DC FAN MOTOR
The highly efficient DC brushless motor reduces the power consumption of the motor body
from 2 W to 4 W with the same output. Also, the lower heating value prevents cabinet
temperature rise and improves the refrigeration unit operating efficiency, resulting in energy
saving effects.
[c] CONTROLLER BOARD
To save energy, HRE series stops energizing the Frame Heater for a maximum of 15
minutes during a defrost cycle (HFE series has an energizing control).
[d] REFRIGERATION UNIT
Provided with the best matched Capillary Tubes for refrigerant control.
Plastic Unit Base and Unit Frame in shape to minimize heat input/output.
Corrosion resistant aluminum Evaporator with boehmite treated and clear coated surfaces.