36
⑨
Compressor
Electrical part defective (constant speed compressor only)
- Run/Start Capacitor ruptured/deformed
- Capacitor defective
Check resistance between terminals
Gradually reduces: No problem
0
ȍ
from start: Defective
- Starter defective
Loose terminal, no conductivity, damaged
- Overload Relay defective
Loose terminal, no conductivity, damaged
⑩
Sheath Heater
Open circuit
Correct
Conductivity
Replace
Insulation resistance 1M
ȍ
or more at 500V
Replace
⑪
Cam Timer
Fast-on terminal disconnected
Correct
Coil circuit open
Replace
⑫
Thermostat
Open circuit
Correct
Conductivity
Replace if not conductive
⑬
Condenser Fan Motor Open circuit
Correct
Locked (not rotating with voltage)
Replace
Internal fuse blown (coil not conductive)
Replace
Abnormal noise
Replace
⑭
Interior Fan Motor
Open circuit
Correct
Locked (not rotating with voltage)
Replace
Abnormal noise
Replace
⑮
Defrost Heater
Open circuit
Correct
Conductivity
Replace
Insulation resistance 1M
ȍ
or more at 500V
Replace
⑯
Thermal Fuse
Conductivity
Replace
Relay contact fused
Replace Relay/Relay Board
⑰
Refrigeration Circuit
Operate constantly at 55Hz in operation setting mode
Replace Capillary/Expansion Valve
Clogged
Discharge pressure: High
(Replace Drier at same time)
Suction pressure: Low (vacuum)
⑱
Refrigerant Leak
Discharge pressure: Low
Locate leakage and replace
Suction pressure: High
(Replace Drier at same time)
CHART
NO.
COMPONENT
CHECK
REMEDY
Содержание HFE-140B Series
Страница 6: ... 2 DIMENSIONS SPECIFICATIONS a HRE 70B ...
Страница 7: ... b HRE 140B ...
Страница 8: ... c HFE 70B ...
Страница 9: ... d HFE 140B ...
Страница 10: ... e HRE 70B F ...
Страница 11: ... f HRE 140B F ...
Страница 12: ... II TECHNICAL INFORMATION 1 WIRING DIAGRAM a HRE 70B ...
Страница 13: ...10 b HRE 140B ...
Страница 14: ...11 c HFE 70B ...
Страница 15: ...12 d HFE 140B ...
Страница 16: ...13 e HRE 70B F ...
Страница 17: ...14 f HRE 140B F ...
Страница 18: ...15 2 REFRIGERATION CIRCUIT Refrigerant HFC 134a HRE series HFC 404A HFE series ...