Maintenance overview
Maintenance location
Work instructions
Interval
After 10 operating hours
Retighten all screw and plug-in
connections as well as the hydraulic
connections.
Even firmly tightened screw connections can come loose (e.g.
because of material settlement or paint residues between the
screw elements). This can lead to loose screw connections
and leaking hydraulic connections.
once
Before the season
Complete machine
Read the operating instructions carefully as a refresher.
Check all screw connections for firm seating and retighten as necessary
Check condition and function of all protective features and replace, if
necessary
Check electrical lines for damage and replace, if necessary.
In use
Hydraulics
WARNING
Lower all hydraulically lifted parts (e.g. wings, packer, undercarriage,
etc.) to the ground before performing any work on the hydraulic system.
Depressurise the hydraulics on the tractor and implement side! Empty
the pressure accumulators.
Allow hydraulic oil and hydraulic components heated during operation to
cool down before any work on the hydraulic system.
Observe the notes on hydraulics in the chapter
Safety and responsibility
.
Hydraulic system and components
Check all hydraulic components and hoses for function,
leak tightness, fastening and chafing
40 h
Hydraulic hoses
Check the hydraulic hoses regularly for damage (cracks, chafing, etc.).
Replace damaged and faulty hoses immediately.
Hydraulic hoses must be replaced after 6 years. For this purpose pay
attention to the manufacturing date on the crimp sleeve (year/month)
and the hose (quarter/year):
Crimp sleeve
Hose
Depending on the conditions of use (e.g. weather influences) or in case
of higher strains on the machine the hoses may need to be replaced
earlier.
Have the hydraulic system checked by an expert at least once every
year.
In addition follow the country specific regulations and directives.
Electrics
Electrical lines
Check for damage
40 h
Pneumatic system
Fan, seed hoses and fall sluice
Leaks, crushing and chafing points, blockage
daily
Distributor
Check for leak tightness, blockage, clean the distributor
daily
Motorised valves
Check switching function
daily
Express TD