Marking tram line valves (position
open
)
If the tram line distribution box is equipped with
a track width change-over, the track width must
only be changed when the valves are open.
This can be checked on the terminal (no tram
line must be switched) or by checking the marks
on the valves.
Seed flow monitoring (option)
The seed flow sensors enable the monitoring of
up to 120 seed and fertiliser hoses.
The sensors are connected in series, and the
numbers indicate the order.
In case of an alarm, these sensor numbers help
when troubleshooting the hoses.
If the monitored seed hoses are also fitted with
valves for the tram line control, these numbers
must also be entered in a list in the terminal
menu of the tram line rhythms - see
E-Manager
instructions.
54
55