Parking
DANGER
Risk of accident due to insufficient stability
¾
Park the machine on a flat and paved surface.
NOTE
Before parking for an extended period:
¾
Park the machine in a hall or under a roof.
¾
Clean the machine and prepare it accordingly,
see chapter
Care and maintenance.
1. Position the machine at a suitable location
and set the tractor brake.
2. Lock the control units.
3. Disconnect hydraulic and electrical connec-
tions and place them into the hose cabinet.
4. Turn the support down and secure it with bolt
and cotter pin.
5. Empty the seed hopper.
6. Relieve and uncouple the upper link.
7. Uncouple the tractor link arm and lower it.
8. For fan with PTO-shaft drive:
-
Switch off the PTO-shaft.
- Remove the PTO-shaft pump and hook it
in the bracket.
9. Reduce the coulter pressure adjustment to
relieve the rubber elements.
10. Empty and clean the metering unit.
11. Lock the seed hopper cover.
12. Store the terminal in dry conditions.
34