11
Measurement
This section describes the basic measuring method of each measurement parameter.
Preparation ................................................................................. 12
Confirmation before starting measurement ..................................... 12
Turning ON the instrument................................................................. 13
• Inserting the batteries .......................................................................................... 13
• Using the AC adapter (option)............................................................................. 14
• Pressing the POWER key ................................................................................... 14
Setting the date and time.................................................................... 15
Connecting an electrode .................................................................... 16
pH measurement........................................................................ 17
Setting the instrument ........................................................................ 17
• Setting temperature compensation (default: ATC) .............................................. 17
• Setting the standard solution used for calibration (default: NIST) ....................... 18
• Standard solution type......................................................................................... 19
Performing calibration ........................................................................ 20
• pH standard solution setting is NIST or USA....................................................... 20
• Inspecting repeatability........................................................................................ 23
• pH standard solution setting is CUST.................................................................. 24
Performing measurement................................................................... 27
mV, ORP measurement ............................................................. 28
Setting the instrument ........................................................................ 28
Switching between absolute value and relative value..................... 29
Performing measurement................................................................... 30
Dissolved oxygen measurement .............................................. 31
Setting the instrument ........................................................................ 31
• Setting temperature compensation (default: ATC) .............................................. 31
• Setting salinity correction (default: 0.0 PPT) ....................................................... 33
• Setting air pressure correction (default: 1013 hPa)............................................. 34
• Setting the industrial standard (default: ISO) ...................................................... 35
Performing calibration ........................................................................ 36
• Performing air calibration .................................................................................... 36
• Performing calibration using the standard solution.............................................. 38
Performing measurement................................................................... 41