W8710A EQUIPMENT MONITORING SYSTEM
5
68-0256
Fig. 4. Conventional wiring diagram.
Fig. 5. Heat pump wiring diagram.
Wiring External Air Temperature Sensor (Use
with Heat Pump Systems)
Connect the external air temperature sensor to the W8710A
terminals. For instructions on mounting the sensor, see
instructions packaged with the sensor.
NOTE: The W8710A has a factory default outside air tem-
perature setting of 46°F (8°C) that can be used
instead of an external air temperature sensor in mod-
erate climates. But when maximum accuracy is
desired, install the 32005321-001 External Air Tem-
perature Sensor to override the 46°F (8°C) default
setting.