3. Installation
3.10. Rotate display
28
SmartLine Wireless User's Manual
Revision 2
CAUTION
Take precautions against electrostatic discharge to prevent damaging the
display/sensor module.
Display adjustment
Step
Action
1
Honeywell recommends that the transmitter be removed from service and moved to a
clean area before servicing.
2
Loosen the M3 locking set screw on the display end-cap. See item 1 in
Figure 3-15
.
Unscrew and remove the end cap.
3
Loosen the two captive screws on the display/sensor module. See items 2 in
Figure
3-15
.
4
Rotate the display 90 degrees in either direction so the screws line up with the
threaded holes. Do not rotate more than 90 degrees or you could damage the wires
behind the display.
5
There are two connectors on the back of the display/sensor module, J4 and J5, either
of which can be used to connect to the meter body cable. If required, move the meter
body cable to the other position.
6
Re-
attach the display’s two captive screws. Tighten to 0,4 – 0,6 Nm (3.5 – 5.3 lb-in.).
7
Replace end cap and tighten M3 locking screw.
Figure 3-15: Display rotation
Содержание SmartLine
Страница 2: ......
Страница 8: ......
Страница 14: ...xiv SmartLine Wireless User s Manual Revision 2 ...
Страница 108: ...94 SmartLine Wireless User s Manual Revision 2 Appendix B Certifications and Approvals B1 EU Declaration of Conformity ...
Страница 109: ...Revision 2 SmartLine Wireless User s Manual 95 ...
Страница 110: ...96 SmartLine Wireless User s Manual Revision 2 ...
Страница 111: ...Revision 2 SmartLine Wireless User s Manual 97 ...
Страница 119: ...Revision 2 SmartLine Wireless User s Manual 105 B5 Control Drawing ...
Страница 120: ...106 SmartLine Wireless User s Manual Revision 2 ...
Страница 121: ...Revision 2 SmartLine Wireless User s Manual 107 ...
Страница 122: ...108 SmartLine Wireless User s Manual Revision 2 ...
Страница 123: ...Revision 2 SmartLine Wireless User s Manual 109 ...
Страница 128: ...114 SmartLine Wireless User s Manual Revision 2 This page has been intentionally left blank ...