If the antenna is smaller than the process connection:
•
Make sure the flange on the nozzle is level.
•
Make sure that you use the applicable gasket for the flange dimensions and the process.
•
Align the gasket correctly on the flange facing of the nozzle.
•
Lower the antenna carefully into the silo.
•
Tighten the flange bolts.
i
Refer to local rules and regulations for the correct torque to apply to the bolts.
Equipment needed:
•
3 mm Allen wrench (not supplied)
If the antenna is larger than the process connection:
•
Make sure the flange on the nozzle is level.
•
Remove the antenna locking screw from the part below the flange.
•
Remove the antenna from the part below the flange.
•
Align the gasket correctly on the flange facing of the nozzle.
•
Put the device carefully on the silo flange. Do not attach the device flange to the silo yet.
•
Attach the antenna to the device inside the tank. Go to the top of the tank.
•
Lift the device a small distance. Attach the antenna locking screw to the part below the flange.
Tighten the antenna locking screw.
•
Put the device carefully on the silo flange. Tighten the flange bolts.
Figure 3-9: How to attach the device if the antenna is larger than the process connection
WARNING!
If you attach the antenna in a closed space, make sure that there is a good airflow in the area.
Make sure that a person not in the silo can always hear you.
Содержание SmartLine RM60
Страница 4: ...4 www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ABOUT THIS DOCUMENT SMARTLINE RM60 FMCW ...
Страница 8: ...CONTENTS 8 www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US SMARTLINE RM60 FMCW ...
Страница 16: ...1 SAFETY INSTRUCTIONS 16 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Страница 34: ...3 INSTALLATION 34 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Страница 40: ...4 ELECTRICAL CONNECTIONS 40 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Страница 76: ...6 OPERATION 76 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Страница 86: ...7 SERVICE 86 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Страница 104: ...8 TECHNICAL DATA 104 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Страница 114: ...9 DESCRIPTION OF HART INTERFACE 114 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Страница 126: ...10 APPENDIX 126 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Страница 127: ...APPENDIX 10 127 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...