Appendix
User manual for HON R100 gas pressure regulator with HON P095NG pilot
89
10.4
Lubricants and threadlockers
Important!
All parts must be slightly greased.
Use the following lubricants:
Application
Remark
Lubricant
Part no.
O‐rings
Stationary and moving
Standard model:
Flat gaskets
Silicone grease (jar)
27079
Diaphragms
Grease the dia‐
phragm grip body on
all sides
Silicone grease (tube)
27081
Do NOT grease the
flat grip
Valve shank sliding surfaces
Grease film only
Low‐temperature model:
Sliding guides
Silicone grease (jar)
27993
Guide bushings
Moving parts in SAV controlgear
and switchgear
High‐temperature model:
Switch jacks and locking sleeves
PFPE grease
102389
Control balls and control rollers
Ball bearing
Valve sleeves and valve sleeve
gaskets in gas pressure regulators
Silicone grease
27052
Setpoint set screws
Power screws
Assembly paste
27091
Thread material combination:
Al/Al
Screw‐in fittings and fastening
screws
Spring plate depressions (pilot)
Devices for oxygen
Important!
Oil‐free and
grease‐free installation; only
antiseize agents are permissible
Upper oxygen
pressure limit:
260
bar at 60 °C
Antiseize agent
28211
Devices for ammonia
Antiseize agent
28211
Application
Remark
Threadlocker
Part no.
Maintenance
(see page 44)
section
Diaphragm units
LOCTITE
26688
Lubricants
Threadlocker