Transport, installation and start‐up
User manual for HON R100 gas pressure regulator with HON P095NG pilot
34
5.2
Installing the gas pressure regulator
Prepare the following materials:
Flange gaskets
Threaded bolts
Washers
Nuts
The quantity and size are dependent on the following criteria:
Design and size of the flange
Assess the installation situation.
The numbers have the following meaning:
Figure
No.
Meaning
1
Gas regulating line inlet
2
Studs and washers
3
Flange gasket
4
Nuts and washers
5
Gas regulating line outlet
Proceed as follows:
Figure
Step
Description
1
Remove the protective plates from the
flange.
2
Transport the device to the location where
it will be installed.
The device needs to be installed in the
piping in a horizontal and level position.
If you want to use a different installation
position, consult with the manufacturer
first.
Pay attention to the direction of flow for
the gaseous fluid as marked on the
body.
3
Secure and support the device’s position in
such a way that the device can be installed
in the piping without any stress and that
the piping’s weight will be supported as
well.
4
Install the flange gaskets.
5
Screw down the flange crosswise in the
specified order. When doing so, make sure
to observe the torques specified by the
flange gaskets’ manufacturer.
Preparing the materials
Assessing the situation
Mounting the actuator
assembly