Galaxy Flex Installer Manual
Program Zones [52]
95
Zone Function menu
01 = Final
14 = PA Silent
28 = Video
02 = Exit
15 = PA Delay
29 = Video Exit
03 = Intruder
16 = PA Delay Silent
32 = Set Log
05 = Security
18 = Spare
33 = Custom-A
07 = Entry
19 = Fire
34 = Custom-B
08 = Push Set
20 = Tamper
39 = Keyswitch Reset
09 = Keyswitch
22 = Beam Pair
40 = Bell Fail
10 = Secure Final
23 = Battery Low
41 = Intr Low
11 = Part Final
24 = Line Fail
42 = Intr High
12 = Part Entry
25 = AC Fail
43 = PSU Fault
13 = PA
26 = Log
44 = Fault
01 Final
Zones programmed as Final initiate the unsetting procedure and terminate setting procedure;
opening the Final zone when the system or group is set starts the entry timer; opening and
then closing the Final zone during the exit procedure sets the system or assigned groups,
providing all the zones are closed. The opening (+) and closing (–) of Final zones during the
setting and unsetting procedures are recorded in the event log.
Pressing
when programming a Final zone doubles the entry time of the group.
Opening a Final zone during the exit time is reported on the keypad as an open zone; the
entry/exit horns bleep rapidly to indicate that the zone is open.
Note:
The termination feature of a Final zone can be extended to terminate the setting of
multiple groups by pressing
when assigning a group to the zone. Refer to the Star
Group Function.
02 Exit
Zones that protect the entry and exit routes are programmed as Exit. During the setting and
unsetting procedures Exit zones have a non-alarm operation. If the Exit zone is activated
while the system is set, without the unsetting of the group being initiated, an Intruder alarm
condition is activated.
Opening an Exit zone during the exit time is reported on the keypad as an open zone; the
entry/exit horns bleep rapidly to indicate that the zone is open.
Note:
The Exit zone can be assigned to multiple groups by pressing
when assigning a
group to the zone. This allows an Exit zone to be activated in a group which is not
currently being unset without activating an Intruder alarm. Refer to the Star
Group