Galaxy Flex Installer Manual
Program Zones [52]
91
Note:
This attribute only works when the
Chime [15]
option is enabled.
4=Omit
Enable the Omit attribute to allow these zone omit functions to be programmed,
11=OMIT
ZONES
,
46=GROUP OMIT
).
The Omit attribute defaults to 0 (disabled) for all zone functions.
Use
A
or
B
to toggle the status of the Omit attribute, and then press
ent
to accept the
programming.
5=Part
Disable the Part attribute to ensure the zone is excluded from the setting procedure when the
part setting options is used to set the system:
13=PART SET
. The Part attribute defaults to
1 (enabled) for all zone functions except zones programmed as
09=Keyswitch
.
Use
A
or
B
to toggle the status of the Part attribute, and then press
ent
to accept the
programming.
6=Resp. Time
This function is only applicable to zones on RIO rev 1.2 and Smart PSU rev 0.7 and above.
Use this option to select either Fast (10 ms), System (default value programmed in
Parameters [51]
, option 27) or Slow (750 ms), for each zone.