Cancel setting
Galaxy Flex Installer Manual
32
To Part Set:
1.
Type your code.
2.
Press
B
.
This is identical to the full setting procedure, except only the zones that have the Part
attribute enabled are included (refer to the
Program Zones [52]
option).
Cancel setting
To cancel setting (during the setting procedure):
Press
esc
.
Unset using a PIN
To unset the system using a PIN:
1.
Type your code.
2.
Press
ent
.
If you don't have group choice, all of the groups assigned to your code are instantly
unset.
If you have group choice only the group that the final or entry zone is assigned to
is unset; all of the other groups remain set. The system displays the set status of the
remaining groups and prompts for the required groups to be unset. To unset the
required groups press the relevant number keys – the
S
or
P
(Set or Part Set)
changes to flashing
U
, and then press
ent
.
When the system/group is unset three short beeps are emitted to advise you that the
system/group is unset.
Engineer unsetting
An engineer can only unset a system that was set using the engineer code. An engineer code
cannot be used to unset a system that was set by a user code.
Keyswitch setting options
Zones programmed as
KEYSWITCH
can be used to full set, part set and unset the system.
Refer to the
Program Zones [52]
option.
Set with a keyswitch
A keyswitch starts the setting procedure of each of the groups assigned to the keyswitch
zone. At the end of the exit time or when the setting procedure is terminated by a final or
PART SET 060
■■■■■■■■□□□□□□□□