22
Installing the Scan Assembly
Attaching the Bubble to an Indoor or Outdoor Pendant Housing
To attach the bubble to the housing:
1.
Clip the safety cable to the bracket on the housing.
2.
Confirm that the o-ring is in place around the bubble and gently push the
bubble against the housing
3.
Install the two screws on the housing to secure the bubble in place.
Figure 3-5
Pendant Housing Bubble Installation
Attaching the Bubble to a Rugged Housing
To attach the bubble to the housing:
1.
Clip the safety cable to the bracket on the housing.
2.
Align the four screw holes on the bubble with the four holes on the housing.
3.
Push the bubble against the housing and tighten the four captive security
screws using the supplied 5/32-inch (4 mm) hex key.
Figure 3-6
Rugged Housing Bubble Installation
Safety cable