7
Device Configuration and Commissioning
enCore FC
Operating Instructions
Page 97 of 120
7.1 Device Configuration
This section gives brief instructions on how to create a complete confi-
guration for enCore devices and how to transfer the configuration into the
device on-site via USB. For details
refer to volume ”Configuration of
Device Software” of the enCore FC manual.
Opening the security switch
As a general rule, there are parameters which cannot be
changed, if the security switch is closed – especially if the device
is used within the scope of legal metrology. If a new
parameterization refers to such a parameter, then the security
switch must be opened, such that the presence of a metrology
expert may be required in some instances.
The following steps are required:
►
Start enSuite on your computer.
►
Establish the USB connection with your enCore device.
►
Use enSuite to create a suitable device parameterization.
►
Open the security switch if required.
►
Transfer the parameterization to the device.
As soon as the transfer of the parameterization begins, a login dialog
appears on the computer screen.
►
Login as an administrator.
Standard login
A standard login as an administrator (user name
admin1
and an
empty password) typically works here if you have not changed the
start-up settings for user administration. Otherwise follow the
individual user configuration of the device.
After a successful login the data transfer begins.
Содержание enCore FC1
Страница 7: ...Contents enCore FC Operating Instructions Page 7 of 120 12 Index 118 13 Appendix 120 ...
Страница 121: ......
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......
Страница 127: ......
Страница 131: ......
Страница 132: ......
Страница 133: ......