Installation
AutoSet 1500 User Manual
15
Ch 2
1088500
10. Determine the correct wiring connections for your strain links. The way you con-
nect the wires depends on whether you mounted the strain links to read tension or
compression forces on the press. Each wiring scheme is shown in Figure 2-7.
shield
+in (wht)
- in (grn)
+exc (red)
-exc (blk)
shield
+in (grn)
- in (w
ht)
+exc (red)
-exc (blk)
Wiring for tension
Wiring for compression
1
2
3
4
5
1
2
3
4
5
Figure 2-7. Wiring connections for strain links
11. Start with connector TB7 for the right strain link (marked right input). Strain link
connectors are the same L-shaped type as used for the AC wires. Pull the L-
shaped top section of connector from base. Make wiring connections in the same
way as for AC wires.
12. Replace the connector. It only goes in one way. Double check connections.
13. Remove connector TB6 for the left strain link (marked left input). Connect wires
from second strain link.
14. Replace the second connector. Double check connections.
15. You are done installing the strain links and connecting them to the AutoSet. Go
on to next section—connecting AC wires to power source.