8-1
S E C T I O N 8
Specifications & Accessories
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
SECURITY CONTROL
1. Physical:
318mm x 368mm x 76mm
2. Electrical:
VOLTAGE INPUT: 16.5VAC from plug-in 25VA minimum transformer
RECHARGEABLE BACKUP BATTERY: 12VDC, 4AH minimum (sealed lead acid type).
Charging Voltage: 13.8VDC.
ALARM SOUNDER: 12V, 2.0 Amp output can drive 12V sirens or can drive one or two 702
(series ) self-contained 20-watt sirens. Do
not
connect two 702s in parallel.
AUXILIARY POWER OUTPUT: 12VDC, 600mA max.
FUSE: Battery (3A) No. 90–12
3. Communication:
FORMAT SUPPORTED:
ADEMCO Express:
10 characters/sec, DTMF (multi-frequency) Data Tones,
1400/2300Hz ACK, 1400Hz KISSOFF.
ADEMCO Low Speed:
10 pulses/sec, 1900Hz Data Tone, 1400Hz ACK/KISSOFF.
Radionics/SESCOA:
20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF.
Can report 0-9, B-F
Robofon 8
See description in Communication section.
ADEMCO Contact ID
10 characters/sec., DTMF (multi-frequency) Data Tones,
1400/2300Hz ACK, 1400Hz KISSOFF.
Robofon Contact ID
same as ADEMCO except 2300Hz ACK
LINE SEIZE: Double Pole
DOC Load No.: 3
4.
Maximum Zone Resistance:
Zones 1–8 = 300 ohms excluding EOLR in standard EOLR
zones