*25
Arming Prevention Override
Entry 1: 0 = no arming prevention override
1 = allow system to arm with an RF
supervision failure
2 = allow system to be armed with an
AC Mains Loss
4 = allow system to be armed with a
system low battery
Entry 2: 0 = no tamper override
1
†
= allow system to be armed with a
tamper fault
2
†
= allow system to be armed with a
tamper fault once
If no override is selected, system will not be able to
be armed when there is either a supervision
failure, system low battery, AC mains loss, or a
tamper condition.
If override is enabled, the user must enter the
arming sequence twice to arm the system; the first
entry of user code + arm command will not arm,
but a second entry of user code +arm command will
arm the system.
E.g., To select arm with “supervision failure” and
“low battery”, enter 5 (1 + 4)
† NOTE:
If tamper option 1 or 2 is selected, field
*175 digit 2 must be “0.”
*26
Chime By Zone List 3
0 = no zone list (chimes on fault of
any
entry/exit
or perimeter zone when chime mode on)
1 = use zone list (chimes on fault of
specific
zones programmed in zone list 3 when
Chime mode on)
If enabled, you can define the specific zones
intended to chime when faulted while the system is
in Chime mode. Use zone list 3 to assign these
zones (see
∗
81
Zone List Programming
section
for details).
*27
Powerline Carrier Device (X-10) House
ID
0 = A
6 = G
# + 11 = L
1 = B
7 = H
# + 12 = M
2 = C
8 = I
# + 13 = N
3 = D
9 = J
# + 14 = O
4 = E
# + 10 = K
# + 15 = P
5 = F
Powerline Carrier devices require a House ID,
identified in this field. Program Powerline Carrier
devices in interactive modes
∗
79, *80 and *81.
*29
ECP Contact ID Output for ACM
0 = not used
1 = use Contact ID output on ECP
If selected, all messages programmed to go to the
primary telephone line receiver will also be sent to
the connected Alternative Communication Media
(ACM), such as a 7845i Internet/Intranet
Communicator or AI4164RS/AI4164ETH Eureka
Network Interface (sent in Contact ID format). The
data line is supervised as well as certain functions
in a long range radio. If communication is lost or a
trouble develops, an attempt will be made to send a
message via both ACM and telephone to the central
station.
Program the ACM for device address 3.
Содержание ADEMCO VISTA-12A
Страница 2: ...ii ...
Страница 26: ...Installation and Setup Guide 2 20 ...
Страница 82: ...Installation and Setup Guide 5 26 ...
Страница 98: ...Installation and Setup Guide 7 4 ...
Страница 104: ...Installation and Setup Guide 8 6 ...
Страница 108: ...Installation and Setup Guide 9 4 ...