Installation and Setup Guide
4-8
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*59
Exit Error Report Code
0 = no report
1-F = report code; see description above
After arming the system, zones remaining open after
exit delay expires cause an alarm sound at the
keypad and external sounder (keypad also displays
“EXIT ALARM”), and entry delay begins. Disarming
before the end of the entry delay stops the alarm
sounding and no message is sent to the central
station. The keypad will display “CA” (fixed-word) or
“ALARM CANCELED” (alpha display).
If the system is not disarmed before entry delay
expires, an “EXIT ALARM” message will be sent to
the central station if Exit Error Report Code is
enabled. The keypad will display “EA” (fixed-word )
or “EXIT ALARM” (alpha display), and alarm
sounding continues until the system is disarmed
(or timeout occurs).
An Exit Alarm condition will also result if a fault
occurs in an exit or interior zone within 2 minutes
following the end of the exit delay, and an “EXIT
ALARM” message will be sent to the central station
With Contact ID format, the message will contain
the zone number and error code 374 (“ALARM–
EXIT ERROR”).
*60
Trouble Report Code
0 = disable; 1-F = see description above
∗
59
Sent if a zone has a trouble condition.
*61
Bypass Report Code
0 = disable; 1-F = see description above
∗
59
Sent when a zone is manually bypassed or is
automatically bypassed at the end of exit delay.
*62
AC Mains Loss Report Code
0 = disable; 1-F = see description above
∗
59
Timing of this report is random with up to a 1-hour
delay. If AC mains restores before the report goes
out, there is no “AC RESTORE” report.
*63
Low Battery Report Code
0 = disable; 1-F = see description above
∗
59
Sent when a low-battery condition exists in the
system’s battery.
*64
Test Report Code
0 = disable; 1-F = see description above
∗
59
Sent periodically to test that the communicator and
phone lines are operational. Frequency of report is
set in Scheduling mode (event 11).
*65
Open Report Code
0 = disable; 1-F = see description above
∗
59
Sent upon disarming of the system in the selected
partitions.
*66
Arm Away/Stay Report Code
1-F = see description above
∗
59
This option allows for independent programming of
Away and Stay reports for each partition.
NOTE:
“OPEN” reports are not sent if the
associated closing report is not enabled.
*67
RF Low Battery Report Code
0 = disable; 1-F = see description above
∗
59
Sent when a wireless transmitter low-battery
condition exists.
*68
Cancel Report Code
0 = disable; 1-F = see description above
∗
59
Sent upon disarming of the system after an alarm
condition was reported.
Содержание ADEMCO VISTA-12A
Страница 2: ...ii ...
Страница 26: ...Installation and Setup Guide 2 20 ...
Страница 82: ...Installation and Setup Guide 5 26 ...
Страница 98: ...Installation and Setup Guide 7 4 ...
Страница 104: ...Installation and Setup Guide 8 6 ...
Страница 108: ...Installation and Setup Guide 9 4 ...