Installation and Setup Guide
4-6
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*50
Burglary Dialer Delay
0 = no dial delay
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
Provides delay of “BURGLARY ALARM” report to
the central station, which allows time for the
subscriber to avoid a false alarm transmission. This
delay does not apply to zone type 24 alarms (silent
burglary) or to 24-hour zone types 6, 7, and 8 (silent
panic, audible alarm, auxiliary alarm), which are
always sent as soon as they occur.
*51
Common Partition Primary Subs. Acct.
No.
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report
format selected in field *48.
*52
Common Partition Secondary Subs.
Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report
format selected in field *48.
*53
SESCOA/Radionics Select/
CID Codes
SESCOA/Radionics:
0 = Radionics (0-9, B-F reporting)
1 = SESCOA (0-9 only reporting)
Contact ID Codes:
0 = disable both Time/Date Inaccurate and
Successful Download/Access reports
1 = enable Time/Date Inaccurate report (code
626);
2 = enable Successful Download/Access
report (code 412)
3 = enable both Time/Date Inaccurate and
Successful Download/Access
SESCOA/Radionics:
Select SESCOA or Radionics format.
Select 0 for all other formats.
Contact ID (CID) Codes:
If desired, enable the
Time/Date Inaccurate and/or Successful
Download/Access report codes. These reports are
valid only when Contact ID reporting format is used.
*54
Dynamic Signaling Delay
0 = disabled (both signals sent)
1–15 = entry times a 15-second delay.
e.g., 1 = 15 seconds, 2 = 30 seconds, etc.
Intended for use with ECP Contact ID Output
reporting via ACM.
This field lets you select the time the panel should
wait for acknowledgment from the first reporting
destination (see
∗
55) before it attempts to send a
message to the second destination. Delays can be
selected from 0 to 225 seconds, in 15-second
increments. This delay is per message. If ”0” is
entered in this field, the control panel will send
redundant reports to both Primary Dialer and ECP
output.