Technical data
52
13 Technical data
Device short description: HM-LC-Sw4-DR
Supply voltage :
230 V/50 Hz
Current consumption:
20 mA
Standby power consumption: 0.4 W
Outputs:
4 potential-free relay
switch outputs
Relay:
Shutter contact
Kind of load:
Ohmic load
Switching capacity (max.): 3680 W
(230 V/50 Hz/16 A) per
channel, total for all chan-
nels max. 25 A (5750 W)
Cable type and cross section: rigid wire 0.14-2.5 mm²;
flexible wire, with ferrule,
0.14–1.5 mm²
Installation:
mounting rail (DIN rail)
according to EN50022
Radio frequency:
868.3 MHz
Receiver category:
SRD category 2
Typ. open area RF range: 200 m
Duty cycle:
< 1 % pro h
Degree of protection:
IP20
Protection class:
II
Ambient temperature:
-10 °C to +55 °C