![HomeMatic HM-LC-Sw4-DR Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/homematic/hm-lc-sw4-dr/hm-lc-sw4-dr_installation-and-operating-manual_2153739043.webp)
Installation
43
Terminal
Function
1.2
Power supply (phase conductor)
1.6
Power supply (neutral conductor)
1.1, 1.5
Phase conductor connection, channel 1
2.1, 2.5
Switched phase channel 1
3.1, 3.5
Phase conductor connection, channel 2
4.1, 4.5
Switched phase channel 2
1.4, 1.8
Phase conductor connection, channel 3
2.4, 2.8
Switched phase channel 3
3.4, 3.8
Phase conductor connection, channel 4
4.4, 4.8
Switched phase channel 4
The switching channels have potential-free relay con-
tacts.
For power supply and supply of external
conductor connections of the switching
channels, only the same phase may be used
for the device.
A total connection load of 25 A may not be
exceeded. Therefore, the supplying phase can
be protected with different fuses.