LP-GAS SYSTEMS — 7
164
2008 IMPERIAL
Alarm
The red LED will
fl
ash and the alarm will
sound whenever dangerous levels of LP-Gas
or natural gas are detected. The detector will
continue to alarm until the gas clears or the
Test/Mute
switch
is pressed.
Alarm Procedures:
1. Turn off all LP-Gas appliances (stove,
water heater, furnace, refrigerator),
extinguish all
fl
ames and smoking
material. Evacuate immediately. Leave
doors and windows open.
2. Turn off primary valve on LP-Gas tank.
3. Determine and repair the source of the
leak. If necessary, contact a quali
fi
ed
professional for service.
WARNING:
DO NOT operate any electric switch. This
can produce a spark and ignite the gas.
CAUTION:
DO NOT re-enter until the problem is
corrected.
Alarm Mute:
Press the
Test/Mute switch
when the detector
is in alarm.
1. The red LED will continue to
fl
ash and
the alarm will beep every 30 seconds
until the gas level has dropped to a
safe level.
2. The LED will
fl
ash green until the end
of the Mute cycle.
3. If dangerous gas levels return before
the end of the Mute cycle, the alarm
will beep four times and return to
phase 1.
4. After two minutes the detector will
return to normal operation (solid green)
or resound the alarm if dangerous levels
of gas remain in the area.
Fault Alarm:
Should the microprocessor sense a fault in
the gas detector, a fault alarm will sound twice
every 15 seconds. The LED will alternately
fl
ash red to green and the
MUTE
switch will
not respond to any command. The gas detector
must be repaired or replaced.
Maintenance
1. Vacuum the dust off the detector
cover weekly (more frequently in
dusty locations) using the soft brush
attachment of a vacuum.
2.
DO NOT
spray cleaning agents or
waxes directly onto the front panel.
This action may damage the sensor,
cause an alarm or cause a detector
malfunction.
LP-GAS EMERGENCY PROCEDURES
CHECKLIST
If you smell gas (a rotten egg or sulfur
smell) at any time, perform the following steps
immediately:
WARNING:
A fire or explosion from ignited gas or
gas fumes can cause serious injury or
death.
POTENTIAL SOURCES OF LP-GAS LEAKS WHEN OPERATING THE MOTORHOME
Cooktop Burners
Oven
Refrigerator
Defective LP-Gas Connection
Defective Regulator
Portable Propane Powered Appliances/Accessories
050250d
050250d
Located in Roadside Fuel Bay
Содержание Rambler Imperial 2008
Страница 16: ......
Страница 18: ......
Страница 51: ...47 2008 IMPERIAL DRIVING SAFETY 2 Weighing Procedure Worksheet Weight Record Sheet 020255c...
Страница 120: ...APPLIANCES 4 116 2008 IMPERIAL NOTES...
Страница 163: ...159 2008 IMPERIAL WATER SYSTEMS 6 AQUA HOT BAY Optional 040602c Cover Attached 040602e Cover Removed...
Страница 194: ...ELECTRICAL SYSTEMS HOUSE 8 190 2008 IMPERIAL ELECTRICAL LAYOUT TYPICAL 060191u...