151
2008 IMPERIAL
WATER SYSTEMS — 6
Dumping the Tanks:
1. Prepare to dump the black tank
fi
rst.
Close the grey water valve.
2. Fill the grey tank to at least 50% by
running water in the shower or sinks.
3. Use the tank monitors (located in
hallway and service bay) to observe
tank
fl
uid levels. Stop
fi
lling when the
grey tank is 50% full.
4. Connect the waste drain hose to dump
station.
5. Open the black water valve. Allow the
black tank to drain.
6. Connect a non-potable water hose, with
pressure regulator, to the
fl
ush system
fi
tting located in the service center.
Turn the
fl
ush lever to the “Black
Tank” position.
7. Turn on the faucet and allow water
to rinse the black tank at least three
minutes. Never operate the system
unattended. Ensure the water
fl
ows
freely though the drain hose.
8. When completed, turn off the faucet
and close the black water valve.
9. Open the grey tank dump valve. Allow
the grey tank to drain.
10. Turn the tank
fl
ush lever to the “Grey
Tank” position.
11. Turn on the external water supply,
and allow water to rinse the grey
tank for at least three minutes. Never
operate the system unattended.
Ensure the water
fl
ows freely though
the drain hose.
12. Turn off the external water supply, and
close the grey tank dump valve.
WARNING:
Operating the flush system unattended
can risk flooding. Use the tank flush
system each time the holding tanks are
cycled. Failure to routinely use the flush
system will result in a clogged spray
nozzle. Turn off the water supply when
finished flushing the tank.
13. When preparing for travel, close both
dump valves. Undo restraining devices
from the hose. Disconnect the hose
from the termination outlet by rotating
the
fi
tting counterclockwise 90º.
14. Raise the hose and drain using hand
over hand method working the hose
towards shore
fi
tting. Rinse the hose
with outside facility and repeat the
hose drain process.
15. Remove the hose from shore
fi
tting.
Install hose in carrier and lock door.
Secure the termination cap (required
by law in some states).
16. If desired, add chemicals to the tanks
to control odor. Follow the directions
given by the manufacturer of the
chemical.
NOTE:
Dump the black tank before driving.
WASTE PUMP (Optional)
The waste pump is a self-priming impeller
pump designed to minimize clogging when
draining the tanks. The system comes with a
1½" outlet hose with an adaptable end and a 13
gallon per minute macerator pump.
To Empty the Black Tank:
It is recommended to wear disposable
gloves, safety glasses and protective
clothing as necessary.
Remove the drip cap at the 1½" hose end
(see illustration).
WARNING:
Be sure to remove the drip cap from
the Sani-Con hose end (see illustration).
Failure to do so will result in damage to
the Sani-Con system.
NOTE:
If the pump is activated while the drip
cap is on the hose end, switch the pump
off and wait at least 30 seconds to allow
pressure to dissipate before removing
the drip cap.
Insert hose end into sewer connection.
Periodically tighten all hose clamps.
The waste pump hose end can be
connected to a 3" or 4" threaded or non-
threaded sewer connection. Ensure the
hose end is installed correctly prior to
operation.
Open the solid waste drain valve at
the plumbing service center by pulling
outward.
Содержание Rambler Imperial 2008
Страница 16: ......
Страница 18: ......
Страница 51: ...47 2008 IMPERIAL DRIVING SAFETY 2 Weighing Procedure Worksheet Weight Record Sheet 020255c...
Страница 120: ...APPLIANCES 4 116 2008 IMPERIAL NOTES...
Страница 163: ...159 2008 IMPERIAL WATER SYSTEMS 6 AQUA HOT BAY Optional 040602c Cover Attached 040602e Cover Removed...
Страница 194: ...ELECTRICAL SYSTEMS HOUSE 8 190 2008 IMPERIAL ELECTRICAL LAYOUT TYPICAL 060191u...