107
2008 IMPERIAL
APPLIANCES — 4
Reservoir:
The coolant reservoir
is located in the curbside
fuel tank compartment.
Check the reservoir level
monthly. Inspect the
coolant level when the
diesel burner has just shut
off. The coolant should be
at the Full Hot level. Add
coolant to the reservoir
when the Aqua-Hot is at
operating temperature to
prevent over
fl
ow when
the system attains normal
operating temperature.
Disinfecting:
The tubing inside the Aqua-Hot is rated for
fresh water and winterizing solutions. The
potable water system can be periodically
disinfected by
fl
ushing a solution through the
Aqua-Hot. This solution must be thoroughly
rinsed. Failure to thoroughly rinse the system
with fresh water may result in damage to the
Aqua-Hot.
CAUTION:
If not properly and thoroughly rinsed,
bleach or other concentrated chlorine
bearing chemicals can cause failure to
the tubing inside the Aqua-Hot domestic
water loop.
Annual Tune Up:
Perform an annual Aqua-Hot tune up
consisting of a fuel nozzle and fuel
fi
lter
replacement and a thorough cleaning of the
combustion chamber. A tune up will allow
service personnel to inspect for additional
wear of other components. Signs that the
Aqua-Hot may need servicing are continuous
white exhaust smoke or poor ignition start up.
When in operation, the Aqua-Hot should have
a smooth, high-pitched whine. Loud growls or
other abnormal noise indicates service or repair
is required.
CAUTION:
Disconnect all power supplies before
cleaning or servicing.
Winterize the Aqua-Hot:
The Aqua-Hot can remain on during the
winter months or it must be winterized with
FDA approved RV antifreeze to prevent freeze
damage. The RV antifreeze must be pumped
through the Aqua-Hot until the solution appears
at the hot water side of a faucet.
The on-board water pump can be used
(see illustration), or a separate pump can
be hooked to the city water
fi
tting. Refer to
the Aqua-Hot owner’s manual for complete
winterizing instructions.
If the Aqua-Hot is not winterized, it must
remain operational. If the system is operating
from electric and there is a power outage, freeze
damage may occur.
WARNING:
DO NOT operate the diesel burner
when the motorhome is located inside
a building. Lethal levels of Carbon
Monoxide can accumulate.
CAUTION:
If the motorhome is hooked to shore
power during the winter months and the
Aqua-Hot is operating on the electric
element, a temporary power outage can
freeze the system resulting in damage.
CAUTION:
Failure to winterize the Aqua-Hot with
Non-Toxic FDA approved RV antifreeze
during freezing temperature will result
in serious damage to the Aqua-Hot.
Refer to the Aqua-Hot owner’s manual
for detailed winterizing instructions.
040469
Located in the
fuel bay
040546
Winterizing the Aqua-
Hot diagram
Содержание Rambler Imperial 2008
Страница 16: ......
Страница 18: ......
Страница 51: ...47 2008 IMPERIAL DRIVING SAFETY 2 Weighing Procedure Worksheet Weight Record Sheet 020255c...
Страница 120: ...APPLIANCES 4 116 2008 IMPERIAL NOTES...
Страница 163: ...159 2008 IMPERIAL WATER SYSTEMS 6 AQUA HOT BAY Optional 040602c Cover Attached 040602e Cover Removed...
Страница 194: ...ELECTRICAL SYSTEMS HOUSE 8 190 2008 IMPERIAL ELECTRICAL LAYOUT TYPICAL 060191u...