6 Optional motor versions
Operating manual mzr-7240
Last update: March 2019
Technical data subject to change without prior notice!
39
=
–
+
external voltage
24 V DC
serial
interface
of PC
alternative
power supply
24 V DC
status LED
potentiometer
3
G
N
D
6
F
a
u
lt
O
u
t
4
2
4
V
D
C
5
A
n
a
lo
g
I
n
p
u
t
7
A
n
a
lo
g
G
N
D
8
R
x
D
9
T
x
D
1
0
D
ig
.
In
p
u
t
mzr-Pump / Motor
Power In
2
2
4
V
D
C
/
4
A
0
Speed
Status
Re a d y : g re e n
Fa u l t: re d
0(4)...20 mA
0...10 V
Poti
Mode
1
G
N
D
Terminal Box S-G05
HNP M ikrosystem e Gm bH
Analog
Extern
1
2
In
A
n
a
lo
g
1
1
G
N
D
motor cable
figure 25
Connection of the micro annular gear pump to the power supply
Wire
Function
Terminal Box
blue
Ground
GND
pink
Voltage supply
24VDC
brown
Analog input
Analog Input
white
Error output
Error Out
gray
Ground analog input
Analog GND
yellow
RS-232 interface signal reception
RxD
green
RS-232 interface signal transmission
TxD
red
Digital input
Dig.Input
table 26
Wire configuration between the drive and the Terminal Box S-G05
The speed setting in operation of the micro annular gear pump is to implement
the functions from chapter 6.5.2. The connection of an external potentiometer