DIPROG
;Disable Program
ANSW1
;Asynchron Answer activated
HP7
;Hard Polarity
HB0
;Hard Blocking
HD0
;Hard Direction
HOSP100
;Load Homing Speed
SHA0
;Home Arming deactivated
SHL0
;Hard Limit deactivated
SHN0
;Hard Notify deactivated
CAHOSEQ
;Capture Homing Sequence
ADR
;Analog Direction Right
NODEADR0
;Define Node Address
LPC400
;Load Peak Current Limit [mA]
LCC220
;Load Continius Current Limit [mA]
AC1000
;Load Command Acceleration [U/s²]
DEC1000
;Load Command Deceleration [U/s²]
POR1
;Load Velosity Proportional Term
I20
;Load Velosity Integral Term
PP140
;Load Position Proportonal Term
PD6
;Load Position D-Term
CI16
;Load Current Intergral Term
SR18
;Load Sampling Rate [ms/10]
CORRIDOR100 ;Load Corridor
SP6000
;Load Command Velocity [U/min]
SIN0
;Sinus Commutation
MV0
;Minimum Velocity
MAV25
;Minimum Analog Voltage
SETPLC
;Set PLC Inputs
LL600000000 ;Load Position Range Limits
LL-600000000 ;Load Position Range Limits
LPN10
;Load Puls Number
STW1
;Load Step Width
STN16
;Load Step Number
ENCRES64
;Load Encoder Resolution
V0
;Select Velocity Mode
LR0
;Load relative target position
M
;Move to target position
ENPROG
;Enable Program - start the program sequence immediately after power-on
Listing 2