J1939 Status Codes
The status codes for the J1939 interface are displayed by the Anybus-X Configu-
ration Tool in the network configuration pane associated with the J1939 network.
There are 2 status codes: a general status, and an error status. The general status is
displayed as a textual status. The error status codes are bit strings, so the values
are displayed in hexadecimal format to make them easier to decipher.
J1939 General Status
J1939 Error Status
Value
Description
Initializing
The J1939 network interface is initializing.
Offline
The module is not participating in J1939 network activity.
Online
The module is online and participating in J1939 network activ-
ity.
Table 8-5 J1939 General Status Values
Bit
Description
0
The address claim has failed. The JMI was unable to claim a unique
J1939 network address and join network activity.
1
The CAN error counter has exceeded its warning limits at least one time
since bootup or the last fault reset.
2
The CAN controller has reported a bus-off condition at least one time
since bootup or the last fault reset.
3
A CAN receive overrun condition was detected at least one time since
bootup or the last fault reset.
4
A J1939 transport protocol error has occurred at least one time since
bootup or the last fault reset.
5
A receive message queue has overflowed at least one time since bootup
or the last fault reset.
6
A transmit message queue has overflowed at least one time since
bootup or the last fault reset.
7-15 Not used.
Table 8-6 J1939 Error Status Bit Definitions