EtherNet/IP 4-7
© 2005 HMS Industrial Networks
AB7665 User manual
Status Assembly
The status assembly is a collection of status and diagnostic information for the
Anybus-X J1939 interface. The information in the assembly is updated once a
second.
Byte
Offset
Size
in Bytes
Data Type
Name
Description
0
2
UINT
J1939 Interface
Status
The current status of the J1939 inter-
face. The following values are
defined:
0x8000 Offline
0x8001 Online
0x8002 Initializing
2
2
16-bit bit
string
J1939 Interface
Faults
The current fault status of the J1939
interface. See the bit definitions
below.
4
2
UINT
CAN Error
Counter
The number of CAN errors that have
been accumulated. This counter is
reset by the fault reset command bit.
6
2
UINT
CAN Bus-Off
Counter
The number of CAN bus-off errors
that have occurred. This counter is
reset by the fault reset command bit.
8
2
UINT
CAN Overrun
Counter
The number of CAN receive overrun
errors that have occurred. This counter
is reset by the fault reset command bit.
Table 4-8 Status Assembly Format