Assembly and connection
29
Assembly Instructions
Linear Tables HT-L
HTL-01-0-EN-1905-MA
6.1.4 Mounting with clamping profiles
The clamping profiles must always be attached in pairs to the left and right of the axis body (see Fig. 6.15 and Fig. 6.16). The
required number of clamping profiles depends on the external load. To calculate the required number, the load values listed
in Table 6.2 (clamping force per clamping profile; permissible axial operating force in tension direction per clamping profile)
must be taken into account. Don’t drop below the minimum number of clamping profiles specified in Table 6.2. The distances
between the mounting points are to be selected depending on the load situation. The recommended distances L
SX
listed in
Table 6.2 are only reference values.
X
Drill mounting holes in the mounting surface (hole spacing listed in Table 6.2).
X
Clean mounting surface and position linear table on it.
X
Swivel the clamping profile into the side groove.
X
Secure the clamping profile with a small tightening torque on the bolts.
X
Now tighten the bolts with the full tightening torques, proceeding in a crosswise manner.
99
The linear table has now been installed.
Observe the L
SY
hole spacing (Fig. 6.14) when securing the linear tables.
Precision requirements for all reference surfaces for securing the axis profile.
L
SY
L
B
F
A
0.2 mm/m
Fig. 6.14
Hole spacing for the lateral securing of linear tables with clamping profiles
L
SX
L
SY
40
Fig. 6.15
Securing with clamping profiles – HT150L
L
SX
L
SY
40
40
Fig. 6.16
Securing with clamping profiles – HT200L, HT250L
Содержание 25.12345
Страница 1: ...Assembly Instructions Linear Tables HT L www hiwin de Valid from serial no HSN0000000001...
Страница 61: ...61 Assembly Instructions Linear Tables HT L HTL 01 0 EN 1905 MA Notes...
Страница 62: ...62 Assembly Instructions Linear Tables HT L HTL 01 0 EN 1905 MA Notes...
Страница 63: ...Appendix 2 Declaration of Incorporation 63 Assembly Instructions Linear Tables HT L HTL 01 0 EN 1905 MA...