32
Assembly and connection
Assembly Instructions
Linear Tables HT-L
HTL-01-0-EN-1905-MA
6.5 Setting the switching distance
The limit switches are inductive units and need a defined switching distance of 0.8 mm (±0.2 mm) to the damping element.
X
Move the carriage until the damping element is above a limit switch. Using a feeler gauge, align the damping element
for a switching distance of 0.8 mm (±0.2 mm). Make sure in doing so that the damping element remains parallel to the
carriage’s lower edge.
X
Tighten the bolts for the damping element. The tightening torque is 1 Nm.
X
If a second limit switch has been installed: Move the carriage until the damping element is above the second limit
switch, and check with a feeler gauge that the switching distance is 0.8 mm (±0.2 mm). Correct where necessary until
the switching distance is reached for both limit switches.
X
Route the limit switch cable into the lower groove. There the cable is protected under the groove cover. The groove
cover is available separately, see Section 11.4.
9
9
The switching distance has now been set.
Fig. 6.20
Setting the switching distance with a feeler gauge, and tightening the bolts
Fig. 6.21
Mounting the limit switch: Routing the cables