8.
Faults
8.1 HT-L linear table system malfunctions
Fault
Possible cause
Remedy
Carriage not moving
Load too high
Reduce load or drive acceleration
Carriage backlash
and inaccurate
positioning
Guiding or drive element backlash after
a collision or from extreme effects
(impacts, peak loads, etc.) from outside
Send axis to HIWIN for repair
Limit switch not
working
Switching distance too large
Adjust switching distance to correct value
Limit switch defect or cable break
Replace limit switch
Signal not arriving at controller
Check input line to controller
Noise and vibrations
at high speeds
Tensions in the system
Install axis free of tension; check flatness of bearing
surface and attached load
Wrong drive controller settings
Retune, and adjust controller settings to the applica-
tion conditions
Noise generated by
guiding mechanisms
Lack of lubricant
Relubricate
Damage to guiding mechanisms, e.g.
as a result of extreme impact on the
carriage or extreme contamination
Send axis to HIWIN for repair
Motor load rising,
controller shut-
ting down owing to
overload
Tensions in the system or lack of
lubrication
Install axis free of tension; check flatness of bearing
surface and attached load. Relubricate axis
Heavy contamination on the axis and
internal guiding mechanisms
Clean axis, reinstate free movement of guiding and
drive elements
Motor does not start
Supply cables disconnected
Check connections, plug contacts may be compressed,
repair if necessary
Fuse has tripped via motor protection
Check motor protection for the right settings, remedy
defects if necessary
Table 8.1
Table of HT-L linear table malfunctions
Danger of impacts and crushing
If the axes are moved by the motor, injuries can be caused by moving axes and attachments (energy chains,
attachments installed by customer).
X
Isolating protective equipment must be provided for linear table operations!
CAUTION!
Warning! Electric shock or burns by contact with live parts!
Contact with live parts can result in injuries.
If the customer installs cables incorrectly, the constant motion inside the energy chain can cause chafing and
expose the electrical contact points.
X
Controller design complying with DIN EN 12100. No start after:
– power connected, reinstated!
– troubleshooting!
– machine stop!
X
Only qualified personnel may install cabling!
X
Only qualified personnel may work on electrical installations!
CAUTION!
Содержание 25.12345
Страница 1: ...Assembly Instructions Linear Tables HT L www hiwin de Valid from serial no HSN0000000001...
Страница 61: ...61 Assembly Instructions Linear Tables HT L HTL 01 0 EN 1905 MA Notes...
Страница 62: ...62 Assembly Instructions Linear Tables HT L HTL 01 0 EN 1905 MA Notes...
Страница 63: ...Appendix 2 Declaration of Incorporation 63 Assembly Instructions Linear Tables HT L HTL 01 0 EN 1905 MA...